Can a home battery run your air con overnight in a Perth summer?
Updated 21/11/2026
Home › Blog › Battery and air con
Can a home battery run your air con overnight in a Perth summer?
Perth summers mean air con running well into the evening, which is exactly when power is most expensive. A battery can carry it, but only if it is sized for your air con and your house at the same time. Here is how to work it out from the label on your unit.
By the Solar Red team · 7 minute read
The short answer
- Yes, if it is sized for it: a split system on a mild setting is very achievable. Ducted air con overnight needs a big battery.
- Two numbers matter: battery capacity in kWh (how long) and battery output in kW (how much at once).
- Use the input power, not the cooling capacity, from your air con’s label or spec sheet.
- Pre-cool on solar: cooling the house hard before 3pm means the battery has less to do at night.
- Backup is different: running air con during a blackout depends on which circuits are backed up.
In this guide
Capacity and output: the two numbers that matter
A battery with plenty of kWh but low output can run out of power when the air con, oven and kettle are all on at once, so the shortfall comes from the grid. A battery with high output but low capacity will run everything, just not for long. For air con you need enough of both.
Find your air con's input power
Air con labels show two kinds of figures. The cooling capacity (for example 7 kW) is how much heat the unit moves. The rated input power is how much electricity it draws, and it is much lower. Use the input figure. It is on the label, the spec sheet or in the manual.
A modern inverter air con also does not run at full power all night. Once the room is cool, it ramps down. Its average draw over a night is usually well below the rated input.
Worked examples
These are example figures to show the method. Use your own unit’s numbers.
| Example | Average draw | Hours | Air con energy |
|---|---|---|---|
| Bedroom split, mild setting | 0.5 kW | 8 (10pm–6am) | 4 kWh |
| Living room split, evening | 1.2 kW | 5 (4pm–9pm) | 6 kWh |
| Ducted reverse-cycle, whole house | 3 kW | 6 (3pm–9pm) | 18 kWh |
Now add the rest of the house: fridge, lights, TV, cooking and hot water if it is electric. Say that is another 6–10 kWh between 3pm and morning. In this example, a home running one bedroom split overnight needs roughly 10–14 kWh of usable storage. A home running ducted air con through the evening is looking at 25 kWh or more.
Make your battery go further in summer
Pre-cool before 3pm
Run the air con harder while the panels are producing. A cooler house holds that cooling into the evening.
Set 24–25°C, not 19°C
Every degree you ask the air con to cool takes more energy. A sensible setpoint stretches the battery much further.
Cool the rooms you use
Zone a ducted system to the bedrooms overnight instead of the whole house.
Size the solar to fill the battery
A big battery only helps if your panels can fill it while also running daytime air con.
What about air con in a blackout?
Covering your bill and running the house in a blackout are separate questions. In a blackout, only the circuits wired to the backup supply keep running, and only up to the battery’s backup output. Many homes back up lights, power points and the fridge, but not ducted air con. If keeping the air con on in a summer blackout matters to you, tell us at the quote stage so we design for it. See home battery backup.
Frequently asked questions
- Can a 10 kWh battery run a split system overnight?
- Often yes, if the split system is set to a mild temperature and the rest of your overnight use is modest. Work out your air con’s average draw multiplied by the hours, add your other overnight use, and compare that with the battery’s usable capacity.
- Can a battery run ducted air conditioning?
- Yes, but ducted systems draw several kilowatts, so you need a battery with high output and a lot of storage, typically 25 kWh or more for evening use. Pre-cooling on solar and zoning help a lot.
- Will my air con work in a blackout with a battery?
- Only if its circuit is on the backup supply and the battery’s backup output can handle it. Most systems back up essential circuits only, so tell us if you want air con backed up.
- Where do I find my air con's power use?
- Look for the rated input power (in kW) on the unit’s label, spec sheet or manual. Do not use the cooling capacity figure, which is much higher than the power it draws.
Want a battery sized for your summer?
Send us your Synergy bill and the model of your air con. We will size the battery and solar so the battery carries your evenings, not just on mild days.
Call 1800 449 733Get a free quoteKeep reading
See our solar battery Perth page for battery brands, rebates and $0 upfront options.
Sources: Synergy: 2026 price changes, Energy Policy WA: New requirements for solar and batteries. Rules, rates and rebates change; we check them again when we quote.
More guides
Batteries 18 kW solar system in Perth: panels, output and who it suits
18 kW solar system in Perth: number of panels, daily output by season, roof space, WA connection rules, battery pairing…
Batteries 10 kW solar system in Perth: panels, output and who it suits
10 kW solar system in Perth: number of panels, daily output by season, roof space, WA connection rules, battery pairing…
Batteries Perth solar battery guides: every question answered in one place
All Solar Red guides for Perth solar and batteries in one place: rebates, choosing a battery, installation, Synergy plans, safety…
- Rebates taken off your price first
- Interest-free options for eligible homes
- Installed by SAA accredited local electricians
- Grid application and VPP setup handled for you
We use cookies to understand how the site is used and to show relevant ads. Necessary cookies are always on. You can accept all, reject all or choose. See our Cookie policy.